CDC logoSafer Healthier People  CDC HomeCDC SearchCDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

Search for NIOSH Publications: NIOSHTIC-2

NIOSHTIC-2 Search Results

      Advanced Search  |  Help  |  About  |  Feedback 
Terms: Unrestrained Acoustic Plethysmograph for Measuring Specific Airway Resistance in Mice 1 - 1 of 1 Bibliographic entries All record(s) shown.
Save All   |   Save Page View Saved    |    Download
Select check boxes to automatically save entries, or use 'save all' or 'save page' links above.

 1 Unrestrained acoustic plethysmograph for measuring specific airway resistance in mice
Authors Reynolds-JS; Johnson-VJ; Frazer-DG 
Source J Appl Physiol 2008 Aug; 105(2):711-717 
Link http://dx.doi.org/10.1152/japplphysiol.00949.2007 
NIOSHTIC No. 20034350 
AbstractAn acoustic whole body plethysmograph was developed to estimate specific airway resistance (sRaw) in unrestrained mice. The plethysmograph uses acoustic principles to measure the thoracic breathing pattern and simultaneously measures the airflow entering and/or leaving the plethysmograph. Similarly to traditional methods utilizing a double-chamber plethysmograph, these measurements were combined to estimate sRaw. To evaluate the new system, we placed six conscious A/J mice individually in a whole body plethysmograph (Buxco System) for a 2-min exposure to aerosolized methacholine chloride dissolved in saline (0, 5, 10, and 20 mg/ml), which is known to increase sRaw in mice. Three minutes after exposure, the mice were transferred to the acoustic plethysmograph for 2 min for data collection. The mean baseline value of sRaw was 0.93 +/- 0.10 cmH(2)O center dot s. A dose-dependent increase in sRaw was shown, with an approximate tripling of sRaw at the highest dose. These results demonstrate the ability of the system to estimate sRaw based on plethysmograph airflow and acoustic amplitude. 
KeywordsLaboratory-animals; Animals; Animal-studies; Plethysmography; Plethysmographs; Air-flow; Breathing; Lung-burden; Lung-function; Statistical-analysis; Acoustic-absorption; Acoustical-measurements; Acoustic-trauma 
ContactJ. S. Reynolds, Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, 1095 Willowdale Road - ms L2101, Morgantown, WV 26505, USA 
CODENJAPHEV 
Publication Date20080801 
Document TypeJournal Article 
Email Addressjsr0@cdc.gov 
Fiscal Year2008 
NTIS Accession No. 
NTIS Price 
Issue of Publication
ISSN8750-7587 
NIOSH DivisionHELD 
Source NameJournal of Applied Physiology 
StateWV 
Page 1 of 1
All record(s) shown.