CDC logo
Safer Healthier People
CDC Home CDC Search CDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

Search for NIOSH Publications: NIOSHTIC-2

NIOSHTIC-2 Search Results

      Advanced Search  |  Help  |  About  |  Feedback 
Terms: 20034679
1 - 1 of 1 Bibliographic entries
All record(s) shown.
Save All   |   Save Page
View Saved    |    Download
Select check boxes to automatically save entries, or use 'save all' or 'save page' links above.
Back to Results
Evaluation of the filtration performance of 21 N95 filtering facepiece respirators after prolonged storage.
Authors
Viscusi-DJ; Bergman-M; Sinkule-E; Shaffer-RE
Source
Am J Infect Control 2009 Jun; 37(5):381-386
Link
http://dx.doi.org/10.1016/j.ajic.2008.09.021 
NIOSHTIC No.
20034679 
Abstract
Background: Organizations are stockpiling respirators to prepare for an influenza pandemic. To better understand the effects of prolonged storage, this investigation evaluated the filtration efficiency of 21 different models of National Institute for Occupational Safety and Health (NIOSH)-certified disposable N95 filtering facepiece respirators. These respirators had been stored in their original packaging for a period of at least six years in research laboratories and dry warehouse facilities, ranging in temperature between 15°C-32ºC and relative humidity between 20-80%RH. Methods: Filter penetration was measured using an abbreviated version of the NIOSH respirator certification test incorporating a polydisperse sodium chloride aerosol at 85 L/min. Results: Of the 21 respirator models tested, 19 models had both average penetration results of less than 5%. Mean initial penetration values ranged from 0.39% to 5.83%, while mean maximum penetration values ranged from 0.95% to 5.83%. There did not appear to be any correlation between the length of storage and failure to pass the filtration test. Conclusions: Results indicate that most N95 filtering facepiece respirators stored for up to ten years at warehouse conditions will likely have expected levels of filtration performance and the degree of filtration efficiency degradation is likely model specific.
Keywords
Filters; Filter-materials; Filter-fabrics; Respirators; Respiratory-protective-equipment; Personal-protective-equipment; Personal-protection; Infectious-diseases
Contact
Ronald E. Shaffer, Ph.D., Chief, Technology Research Branch, National Personal Protective Technology Lab (NPPTL), National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), 626 Cochrans Mill Road, Bui
CODEN
AJICDC
Publication Date
20090601
Document Type
Journal Article
Email Address
RShaffer@cdc.gov
Fiscal Year
2009
NTIS Accession No.
NTIS Price
Issue of Publication
5
ISSN
0196-6553
NIOSH Division
NPPTL
Priority Area
Healthcare and Social Assistance
Source Name
American Journal of Infection Control
State
PA
Page 1 of 1
All record(s) shown.

File Formats Help:

Adobe PDF file
How do I view different file formats (PDF, DOC, PPT, MPEG) on this site?double arrows.