CDC logo
Safer Healthier People
CDC Home CDC Search CDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

Search for NIOSH Publications: NIOSHTIC-2

NIOSHTIC-2 Search Results

      Advanced Search  |  Help  |  About  |  Feedback 
Terms: 20031962
1 - 1 of 1 Bibliographic entries
All record(s) shown.
Save All   |   Save Page
View Saved    |    Download
Select check boxes to automatically save entries, or use 'save all' or 'save page' links above.
Back to Results
Air volume migration from negative pressure isolation rooms during entry/exit.
Authors
Hayden II-CS; Johnston-OE; Hughes-RT; Jensen-PA
Source
Appl Occup Environ Hyg 1998 Jul; 13(7) 518-527
Link
http://dx.doi.org/10.1080/1047322X.1998.10390100 
NIOSHTIC No.
20031962 
Abstract
Negative-pressure isolation rooms (NPIRs) are used to isolate pa­tients who have a suspected or known airborne infectious disease from the general hospital environment. When a person passes through an NPIR doorway, there exists an exchange of air between the isolation room and the area beyond its door. In a recent study, National Institute for Occupational Safety and Health researchers used sulfur hexafluoride tracer gas to examine the magnitude of air volume migration (AVM) as a function of several independent vari­ables. A small cart carried a mannequin through a doorway separating a laboratory NPIR and a sulfur hexafluoride measurement chamber. The configuration provided simulated entry/exit of a healthcare worker through the doorway. Upon completion of experiments using a swinging door (including various cycle speeds for the door), a slid­ing door was installed and the experiments were repeated. In all cases examined, air flow rate differential between the air supplied to, and exhausted from, the NPIR was the only statistically significant factor in determining the level of AVM. Across the range of flow differen­tials examined (50 to 220 ft3/min), AVM ranged from 35 to 65 ft3. This range of AVM remained statistically unchanged regardless of door type, operating speed of the door, or entry to or exit from the NPIR. (Although entry/exit did significantly increase AVM, travel direction, whether entering or exiting the NPIR, did not.) By know­ing the level of AVM during entry/exit through a doorway-a cause of airborne contaminant migration through a facility-a more com­plete assessment of the risk of transmission of an airborne infectious disease is made possible. This study shows that an anteroom or buffer zone outside the contaminated area's doorway will offer a degree of containment during entry/exit not otherwise-obtainable. While this study concerned itself primarily with the engineering control of the transmission of airborne infectious diseases provided by ventilation systems, the results are applicable to any environment where a clean area is separated from a less clean area by a doorway.
Keywords
Aerosols; Aerosol-particles; Disease-prevention; Disease-control; Health-care-personnel; Health-care-facilities; Health-care; Infection-control; Infectious-diseases; Ventilation-systems; Ventilation; Microorganisms
CODEN
AOEHE9
Publication Date
19980701
Document Type
Journal Article
Fiscal Year
1998
NTIS Accession No.
NTIS Price
Issue of Publication
7
ISSN
1047-322X
NIOSH Division
DPSE
Source Name
Applied Occupational and Environmental Hygiene
State
OH
Page 1 of 1
All record(s) shown.

File Formats Help:

Adobe PDF file
How do I view different file formats (PDF, DOC, PPT, MPEG) on this site?double arrows.