CDC logo
Safer Healthier People
CDC Home CDC Search CDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

Search for NIOSH Publications: NIOSHTIC-2

NIOSHTIC-2 Search Results

      Advanced Search  |  Help  |  About  |  Feedback 
Terms: 20024821
1 - 1 of 1 Bibliographic entries
All record(s) shown.
Save All   |   Save Page
View Saved    |    Download
Select check boxes to automatically save entries, or use 'save all' or 'save page' links above.
Back to Results
The effect of ambient aerosol concentration and exercise on portacount quantitative fit factors.
Authors
Zhuang-Z; Lawrence-R; Campbell-D; Coffey-C
Source
American Industrial Hygiene Conference and Expo, May 8-13, 2004, Atlanta, Georgia. Fairfax, VA: American Industrial Hygiene Association, 2004 May; :83
Link
http://www.aiha.org/education/aihce/Pages/default.aspx 
NIOSHTIC No.
20024821 
Abstract
The PortaCount is a quantitative fit-test instrument which uses ambient aerosol to determine respirator fit. Ambient aerosol concentration levels vary greatly among workplaces. The standard fit test currently uses eight one-minute exercises. Considerable time and financial commitments are needed to select a properly fitting respirator for a given worker. The purposes of this study were to determine: (1) if PortaCount fit factors are affected by ambient aerosol concentration, and (2) if any of the exercises are the most critical in determining the overall fit factor. Fit-test data for 30 elastomeric and filtering-facepiece respirator models from a recent NIOSH study were analyzed. Each model was tested on a 25-subject panel using the PortaCount and seven exercises. The analyses determined: (1) if fit factor varies among five levels of ambient aerosol concentration, (2) the frequency of each exercise having the lowest within-fit-test fit factor, and (3) the average within-fit-test ratio of each exercise fit factor to the highest fit factor among all exercises. Ambient aerosol concentration had no practical effect on fit factor. "Reading," "bending," and "moving head up/down" exercises had the lowest fit factor in about 66% of the tests. They also had the lowest average within-fit-test ratios of exercise fit factor to the highest fit factor (0.56, 0.62, and 0.67, respectively). Fit factors for each exercise were found to be highly correlated with fit factors for each of the other six exercises. There was no significant fit-factor difference between the first and second normal breathing exercises. We conclude that the fit test pass/fail criterion need not be adjusted for ambient aerosol concentration level and that "reading," "bending," and "moving head up/down" are the three most critical exercises in determining the overall fit factor. Further study is needed to determine if fit-test procedures can include only these three exercises.
Keywords
Aerosols; Quantitative-analysis; Respirators; Respiratory-protective-equipment; Models
Publication Date
20040508
Document Type
Conference/Symposia Proceedings; Abstract
Fiscal Year
2004
NTIS Accession No.
NTIS Price
NIOSH Division
NPPTL; DRDS
Priority Area
Research Tools and Approaches: Control Technology and Personal Protective Equipment
Source Name
American Industrial Hygiene Conference and Expo, Atlanta, GA, May 8-13, 2004
State
PA; WV
Page 1 of 1
All record(s) shown.

File Formats Help:

Adobe PDF file
How do I view different file formats (PDF, DOC, PPT, MPEG) on this site?double arrows.