CDC logo
Safer Healthier People
CDC Home CDC Search CDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

Search for NIOSH Publications: NIOSHTIC-2

NIOSHTIC-2 Search Results

      Advanced Search  |  Help  |  About  |  Feedback 
Terms: 20021822
1 - 1 of 1 Bibliographic entries
All record(s) shown.
Save All   |   Save Page
View Saved    |    Download
Select check boxes to automatically save entries, or use 'save all' or 'save page' links above.
Back to Results
An evaluation of short-term exposures to metalworking fluids in small machine shops.
Authors
O'Brien-DM; Piacitelli-GM; Sieber-WK; Hughes-RT; Catalano-JD
Source
Am Ind Hyg Assoc J 2001 May/Jun; 62(3):342-348
Link
http://dx.doi.org/10.1080/15298660108984636 
NIOSHTIC No.
20021822 
Abstract
In a study of 23 small machining shops using metalworking fluids (MWFs), real-time air monitoring using an aerosol photometer was performed to investigate the temporal nature of the exposure and to examine the relationship between the instrumental measurements and traditional sampling methods. Time-weighted averages were calculated from the aerosol photometer data and the results were compared to collocated thoracic and 37-mm closed face cassette samplers. The filter samples were analyzed for total mass and the solvent extractable fraction. Depending on the averaging period used, short-term MWF concentrations exceeded 2.0 mg/m3 in 13 to 39% of the plants studied. High short-term exposures were as likely to be found in plants with average concentrations below 0.4 mg/m3 (thoracic-gravimetric) as those above. Regression analyses indicated that the aerosol photometer most closely matched the data obtained from the thoracic fraction of the total mass. In general, the aerosol photometer overestimated the levels determined using the thoracic cyclone and filter, especially when measuring concentrations of water-based fluids. Use of a calibration factor of 0.7 for straight oils or 0.5 for water-based fluids may assist in the interpretation of aerosol photometer measurements if field calibration data are not readily available. Several approaches to determining the calibration factor from field data were evaluated; more complex calibration techniques improved the accuracy of the measurements.
Keywords
Metalworking; Metalworking-fluids; Machine-shop-workers; Exposure-levels; Air-monitoring; Sampling-methods; Aerosols; Aerosol-sampling
Contact
National Institute for Occupational Safety and Health, 4676 Columbia Parkway, Cincinnati, OH 45226
CODEN
AIHAAP
Publication Date
20010501
Document Type
Journal Article
Fiscal Year
2001
NTIS Accession No.
NTIS Price
Issue of Publication
3
ISSN
0002-8894
NIOSH Division
DSHEFS
Source Name
American Industrial Hygiene Association Journal
State
OH
Page 1 of 1
All record(s) shown.

File Formats Help:

Adobe PDF file
How do I view different file formats (PDF, DOC, PPT, MPEG) on this site?double arrows.